Portable V-max HIFU Machine with RF-Enhanced MFU

SKU Ultralift SD Compact

The Ultralift SD HIFU machine gives you the flexibility to offer facial lifting and body contouring with a foldable portable HIFU machine that fits easily into your treatment space. Its MFU and RF technologies help create a more comfortable treatment experience while supporting consistent results. We also provide comprehensive OEM/ODM services, allowing you to customize the product, branding, software, accessories, and packaging around your business and target market.

From Vmax to SD: MFU + RF in one handpiece

The SD handpiece upgrades Vmax point-by-point MFU by adding 2 MHz RF to the same treatment head, creating a combined Synergy Dotting workflow.

SD handpiece diagram showing focused MFU, RF electrodes and combined or separate delivery modes

Focused MFU delivery

The installed SD cartridge directs one micro-focused ultrasound point to the selected depth.

RF around the working area

Electrodes around the treatment head deliver 2 MHz radiofrequency across the surrounding contact area.

Three delivery patterns

The operator can coordinate MFU and RF in Synergy mode, use MFU-only dotting, or apply RF-only rubbing according to the trained protocol.

For clinics and medspas, combining MFU and RF in one SD handpiece keeps both energy steps on one compact platform and reduces handpiece changes during treatment. For aesthetic chains and distributors, it also simplifies equipment configuration, operator training, and after-sales support.

SD and FL handpieces for focused and linear delivery

The two handpieces solve different treatment tasks: SD combines focused MFU with bipolar RF, while FL delivers linear MFU with on-handpiece control.

Four SD handpiece cartridges for 1.5 mm, 3.0 mm, 4.5 mm and 9.0 mm treatment depths

SD handpiece: focused MFU + bipolar RF

A central MFU emitter works with surrounding bipolar RF electrodes, placing focused and broader heating functions in one treatment head.

  • Focused MFU. The installed cartridge directs one focal point to the selected depth for dotting.
  • Bipolar RF. The surrounding electrodes deliver 2 MHz RF across the contact area during rubbing.
  • Treatment Benefits. Combining MFU with bipolar RF maximizes patient comfort while delivering consistent, reliable treatment outcomes.
FL handpiece LCD showing cartridge status, energy, spacing, treatment length and shot controls

FL handpiece: linear MFU with local control

FL delivers smaller MFU focal points in a linear pattern and keeps key treatment information and controls at the operator’s hand.

  • Controlled linear placement. Smaller focal points support more precise placement and are designed to improve treatment comfort.
  • Live treatment data. The LCD displays cartridge status, energy, spacing, treatment length, and used shots.
  • Adjust without stepping away. Energy and shot-count controls can shorten parameter-adjustment time and reduce returns to the 15-inch main screen.

Vmax HIFU machine applications

Diagram mapping face, neck and selected body areas to focused SD or linear FL handpiece delivery
  • Face

    Use FL for planned linear passes across mapped facial zones. Choose SD where the protocol calls for focused dotting and RF from one treatment head.

  • Neck

    Map defined neck zones first, then select SD or FL for the required point-based or line-based placement.

  • Selected body areas

    Match the handpiece and body-use cartridge to the trained protocol for the selected area.

Cartridge configuration and technical specifications

Specification Details Specification Details
Cartridge configuration
Handpieces SD and FL Standard cartridges 7 total: 4 SD and 3 FL
Total cartridge options 10 total: 4 SD and 6 FL Cartridge frequencies 2, 4, and 7 MHz
SD handpiece depth range 1.5–9.0 mm FL handpiece depth range 1.5–9.0 mm
Operating parameters
RF 2 MHz, Levels 1–10 Spacing 1.0–5.0 mm
Line length 5.0–25.0 mm in 1.0 mm steps Operating modes Auto and Manual
Cartridge capacity Manufacturer-listed 20,000 shots per cartridge
System specifications
Touchscreen 15 inches System functions TIS and listed RMS function
Power 200 W Voltage AC 110–220 V
Machine dimensions 400 × 290 × 530 mm Machine weight 15 kg

FAQ

What makes SD different from a traditional Vmax HIFU handpiece?

A traditional Vmax handpiece delivers MFU point by point. The SD handpiece keeps that focused delivery and adds 2 MHz bipolar RF around the same working area. Operators can use MFU, RF, or Synergy Dotting from one treatment head instead of connecting a separate RF applicator.

What is the difference between MFU and RF in this system?

MFU sends focused ultrasound points to the depth selected by the installed cartridge. Bipolar RF distributes 2 MHz radiofrequency across the surrounding contact area. MFU supports focused placement, while RF provides broader surface-area heating. In Synergy mode, a trained operator coordinates both delivery methods in one planned sequence.

What is the difference between the SD and FL handpieces?

SD delivers focused MFU points and 2 MHz bipolar RF through one treatment head. FL delivers smaller MFU focal points in a linear pattern and includes a local display for treatment data and parameter changes. Both handpieces support face, neck, and selected body workflows with the appropriate cartridge.

How does the SD handpiece support treatment comfort?

The SD workflow combines focused MFU with bipolar RF rather than relying only on higher ultrasound output. The supplied training material describes this coordinated delivery as more comfortable than older HIFU systems while supporting consistent treatment outcomes. Actual sensation still varies with the treatment area, settings, and individual sensitivity.

Does treatment usually require numbing cream?

Most clients tolerate the treatment well, and numbing cream is not usually recommended unless the client is extremely sensitive. The operator should still assess sensitivity, treatment area, selected energy settings, and applicable local practice requirements before treatment. Treatment comfort should be monitored throughout the procedure.

How many cartridges are included, and what depth range is available?

The standard configuration includes seven cartridges: four for SD and three for FL. The full range includes ten handpiece-specific options when three optional FL cartridges are added. Both handpieces cover depths from 1.5 to 9.0 mm. Confirm included and optional cartridges in the written quotation.

How many shots does each cartridge provide?

The manufacturer lists a capacity of 20,000 shots per cartridge. Depending on the treatment area and shot count, one cartridge typically supports hundreds of treatments. Actual use varies with the selected area, spacing, line length, and protocol. The cartridge counter should be checked before each treatment.

What is the estimated consumable cost per treatment?

The estimated cartridge cost is typically less than US$5 per treatment. The actual cost may vary slightly depending on the treatment area, selected depths, and number of shots used.

Where can replacement cartridges be purchased?

UK buyers can purchase cartridges directly from Fotromed or from the local UK reseller. Buyers in other markets can order from Fotromed and should confirm whether a local reseller is available. The written quotation should record cartridge depth, quantity, price, lead time, and shipping method.

Can a new HIFU operator use the SD Compact system?

Many buyers start without prior HIFU experience. Live one-to-one training covers theory, protocols, parameter adjustment, machine setup, cartridge selection, practical guidance, and routine care. After the operator completes training and demonstrates mastery, Fotromed provides a training certificate. Local insurer requirements should be confirmed separately.

Is the SD Compact a portable HIFU machine?

SD Compact is a folding desktop system rather than a floor-standing unit. Its machine body measures 400 × 290 × 530 mm and weighs 15 kg, making it easier to position or transport between suitable treatment spaces. It still requires a stable work surface, power connection, safe handling, and appropriate storage for the handpieces and cartridges.

How much does the SD Compact Vmax HIFU machine cost?

Pricing is quotation-based. The final cost depends on the standard and optional cartridge package, order quantity, destination, shipping method, OEM or branding requirements, training, and confirmed support scope. Request a written quotation that lists the machine configuration, included accessories, replacement cartridge terms, and after-sales service.